Large white LED backlight to work in poorly lit areas
Resistance and continuity
Frequency and capacitance
Maximum Voltage ac/dc 600V
10A ac/dc current measurement (20 A overload for 30-seconds max)
Min/Max/Average to record signal fluctuations
CAT III 600 V safety rated
DC millivolts | Range: | 600.0 mV |
Resolution: | 0.1 mV | |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/Resolution: | 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V | |
Range/Resolution: | 600.00 V / 0.1 V | |
Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts1 true-rms | Range: | 600.0 mV |
Resolution: | 0.1 mV | |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) | |
AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V |
Range/Resolution: | 60.00 V / 0.01 V | |
Range/Resolution: | 600.0 V / 0.1 V | |
Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) | |
Continuity | Range: | 600 ? |
Resolution: | 1 ? | |
Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. | |
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω |
Range/Resolution: | 6.000 kΩ / 0.001 kΩ | |
Range/Resolution: | 60.00 kΩ / 0.01 kΩ | |
Range/Resolution: | 600.0 kΩ / 0.1 kΩ | |
Range/Resolution: | 6.000 MΩ / 0.001 MΩ | |
Accuracy: | 0.9 % + 1 | |
Range/Resolution: | 40.00 MΩ / 0.01 MΩ | |
Accuracy: | 5 % + 2 | |
Diode Test | Range/Resolution: | 2.00 V / 0.001 V |
Accuracy: | 0.9% + 2 | |
Capacitance | Range/Resolution: | 1000 nF / 1 nF |
Range/Resolution: | 10.00 µF / 0.01 µF | |
Range/Resolution: | 100.0 µF / 0.1 µF | |
Range/Resolution: | 9999 µF / 1 µF | |
Range/Resolution: | 100 µF to 1000 µF | |
Accuracy: | 1.9% + 2 | |
Range/Resolution: | > 1000 µF | |
Accuracy: | 5% + 20% | |
Lo-Z Capacitance | Range: | 1 nF to 500 µF |
Accuracy: | 10% + 2 typical | |
AC amps true-rms (45 Hz to 500Hz) | Range/Resolution: | 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A | |
Accuracy: | 1.5% + 3 | |
20 A overload for 30-seconds max | ||
DC amps | Range/Resolution: | 6.000 A / 0.001 A |
Range/Resolution: | 10.00 A / 0.01 A | |
Accuracy: | 1.0% + 3 | |
20 A overload for 30-seconds max | ||
Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz |
Range/Resolution: | 999.9 Hz / 0.01 Hz | |
Range/Resolution: | 9.999 kHz / 0.001 kHz | |
Range/Resolution: | 50 kHz / 0.01 kHz | |
Accuracy: | 0.1% + 2 |