VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic AC/DC voltage selection
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True RMS for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30-seconds)
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
CAT III 600 V safety rated

DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/resolution 6.000 A / 0.001 A   10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2