Innovative Multhimeters with current measurements up to 120A AC/DC
Unique Open Jaw technology for AC/DC current measurements
Very compact and as reliable as a tradictional full size multimeter
| DC V | 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ) |
| ±1.0%rdg±3dgt | |
| AC V | 6.000/60.00/600.0V (Input impedance: approx.10MΩ) |
| ±1.5%rdg±5dgt (45 – 400Hz) | |
| DC A | 60.00/120.0A |
| ±2.0%rdg±8dgt (60A) | |
| ±2.0%rdg±5dgt (120A) | |
| AC A | 60.00/120.0A |
| ±2.0%rdg±5dgt (45 – 65Hz) | |
| Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ |
| ±1.0%rdg±5dgt (600Ω/6/60/600kΩ) | |
| ±2.0%rdg±5dgt (6MΩ) | |
| ±3.0%rdg±5dgt (60MΩ) | |
| Continuity buzzer | Buzzer sounds below 35±25Ω |
| Diode test | 2V±3.0%rdg±5dgtOpen-loop voltage: approx. 2.7V |
| Capacitance | 400.0nF/4.000/40.00µF |
| ±2.5%rdg±10dgt | |
| Frequency (AC A) | 100/400Hz |
| ±0.2%rdg±2dgt (100Hz) | |
| ±0.1%rdg±1dgt (400Hz) | |
| Frequency (DC A) | 100/1000Hz/10/100/300.0kHz |
| ±0.2%rdg±2dgt (100Hz) | |
| ±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz) | |
| (Input sensitivity | |
| Current: more than 6A | |
| Voltage: more than 6V [- 10kHz]/more than 20V [10k – 300kHz]) | |
| Conductor size | Ø12mm max. |
| Withstand voltage | 3540V AC for 5 seconds |
| Applicable standards | IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2 |
| IEC 61010-031, IEC 61010-2-032, IEC 61326 | |
| Power source | R03 (1.5V) × 2 |
| Continuous measuring time: | |
| DCV: approx. 150hours, ACA: approx. 25hours | |
| (Auto power save: approx. 15 minutes) | |
| Dimensions | 128 (L) × 92 (W) × 27 (D) mm |
| Weight | 220g approx. (including batteries) |












Reviews